Assessment of the Tricuspid Valve Morphology by Transthoracic Real-Time-3D-Echocardiography
2005
Aim: To demonstrate the feasibility of transthoracic three-dimensional real-time echocardiography (3D-TTE) supplemental to routine assessments of the tricuspid valve and to analyze interrater agreement. Methods: Twenty healthy subjects and 74 patients with right ventricular failure were examined with conventional 2D and additionally 3D-TTE (SONOS 7500, Philips, Netherlands). The 3D exams were performed and recorded by one of two raters. The recordings were evaluated offline and independently by both raters for visualization of morphological and functional features of the tricuspid valve according to a subjective 3-point scale. Statistical analyses were performed for interrater agreement and…
Direct measurement of left ventricular outflow tract by transthoracic real-time 3D-echocardiography increases accuracy in assessment of aortic valve …
2007
Evaluation of aortic valve stenosis is a major clinical application of echocardiography. The widely employed continuity equation requires determination of the left ventricular outflow tract (LVOT) area. We aimed at testing whether direct area measurement in a volume data set is superior to conventional calculation from the LVOT diameter.We performed LVOT measurement in 20 normal subjects and 83 patients with moderate to severe aortic stenosis with a transthoracic real-time three-dimensional echocardiography (3D-TTE) technique in two systolic frames. The off-line 3D-evaluation allows full choice of section planes within the acquired volume data set. The aortic valve area was calculated from …
Multiplane Two-Dimensional versus Real Time Three-Dimensional Transesophageal Echocardiography in Ischemic Mitral Regurgitation
2011
Objectives: Intraoperative three-dimensional (3D) transesophageal echocardiography (TEE) has been suggested to be a valuable technique for the evaluation of the mechanisms of ischemic mitral regurgitation (IMR). Studies comparing multiplane two-dimensional (2D) with 3D TEE reconstruction of the mitral valve using the new mitral valve quantification (MVQ) software are lacking. We undertook a prospective comparison between multiplane 2D and 3D TEE for the assessment of IMR. Methods: We evaluated echocardiographically 45 patients with IMR who underwent mitral valve surgery in our institution. 2D and 3D TEE examinations followed by a 3D offline assessment of the mitral valve apparatus were perf…